Oil Cementing ChemicalsCurrent page: Home > Oil Cementing Chemicals
SUMMERY
- ST310S-P-AL is a high efficient fluid loss additive with high purity and low dosage.
- ST310S-P-AL is applicable in low to medium temperature system and it can be resistant to 98℃。
- ST310S-P-AL has salt resistance to some extent, and is resistant to 10% brine.
- ST310S-P-AL slurry system is stable with little free fluid.
- ST310S-P-AL slurry system has excellent rheological behavior. It doesn’t require adding additional dispersant.
- ST310S-P-AL is suitable for both water and dry mixed. It has no special requirement on the quality of mixing water and is soluble in cold water.
- ST310S-P-AL can be made into dry mixed type ST310S-D-AL through mixing with materials such as slag, silica flour, fly ash; also made into dry and water mixed dual purpose type ST310S-T-AL.The weight percentage of ST310S-P-AL is 40-60% when made into ST310S-D-AL and ST310S-T-AL.
- ST310S-P-AL can be made into liquid product ST310L-AL through dissolving in the water. The weight percentage of ST310S-P-AL is 20%-30% when made into ST310L-AL.
- ST310S-P-AL can be mixed with ST510-AL series products in any proportion, and then the high temperature resistance and salt tolerance can be enhanced.
SPECIAL ATTENTIONS
- ST310S-P-AL is slightly retarded.
- ST310S-P-AL’s dosage should be increased if used in brine system.
- When ST310L-AL prepared with ST310S-P-AL is not used at once, specialized bactericide should be added to extend the expiration period.
PHYSICAL AND CHEMICAL INDICATORS
Appearance |
Bulk Density g/cm3 |
Water-Solubility |
0.315mm Sieve(45 mesh)Residues % |
White or faint yellow powder |
0.70±0.20 |
100% |
<12 |
CEMENT SLURRY PERFORMANCE
Item |
Test Condition |
Technical Indicator |
Initial consistency, Bc |
80℃/45min, 46.5MPa |
≤25 |
Thickening time, min |
120—200 |
|
Fluid loss, ml |
80℃, 6.9MPa |
≤50 |
10% brine fluid loss, ml |
80℃, 6.9MPa |
≤120 |
Free fluid, % |
80℃, Atmospheric Pressure |
≤1.4 |
24h compressive strength, MPa |
≥14 |
|
Composition(fresh water system):API class G(HSR) 700g; mixed water 308g; ST310S-P-AL 7g (1.0%); defoamer 1.4g(0.2%). |
APPLICATIONS
Application temperature: lower than 208℉ (98℃) (BHCT).
Dosage: ST310S-P-AL generally 0.6-2.0% (BWOC), recommended amount 1.0% (BWOC, fresh water system W/C=0.44).
PACKING
ST310S-P-AL is packed with 25kg bag. It can also be packed according to user requirements.